Results (
English) 2:
[Copy]Copied!
1. Press the Manual control inactive door hit the wall but the door still works:
In this case you need to check the controller battery, if press TDK see dim lights on hand means that the battery not enough space to use, need a new battery, You can buy batteries for the controller at the clock shop or supermarket (You asked capacity batteries 12V - 27A, you should remove the hand thing out for control batteries purchase).
in the case of batteries still, you open the lid of the control box to find a red button located in the box, press the red button and then press the button in HDK on TDK TDK to get back box so long unused code box will erase TKD. If acted on, but TDK still not working means your receiver has broken box functionality or broken hand signal to call a mechanic to fix. 2. Doors not reversible, stopping itself when meeting various obstacles: Take the line 2 reverse from the control box (2 wires beginning with ray) tuck into each other when the door is going down. If the door to stop and reverse itself when short 2 wire together means reversing system at the bottom of the core bar. You need to remove the bottom bar to check the first two switches and copper company and replace broken down. In the case of 2-wire tuck into still not reversed, your control box reversal to repair damage or replace . 3. Door controls only go down one by one. must press the button repeatedly to close the book. The phenomenon occurs due to the following reasons: a. Reversing system of rolling door was short: When convolution control box always recognized that there are always obstacles and stop. For type 2 surveys you need to remove cables from the bottom rail on the control box, if the phenomenon does not happen again, the reversal in the segment due to short rails or cables, wires need to check the position was short and sticky tape power b. Broken wall buttons: Button sound wall is 1 circuit switch communication, if broken circuit STOP button will result in open circuit and motor DOORS default always pressed STOP. You need to check the position of the wire wall off or replaced. C. Bottom bar rolling door jam: You need to check the bottom bar rolling door are loosening mode when the door does not come up. 2 hand tugged the bottom of the door when the door goes up. If the phenomenon above all means stick Bottom trapped leading to closed switch always causes a reversal, it is necessary to dismantle and widen the bottom coupling bar and nan door. 4. DOORS was crying all the up or down: The phenomenon of creep by nan door many spokes leading to excess door. When terminally redundant door will cause the spokes on the same stretch and do not deviate nan door. DOORS need terminally truncated so that when the door to door only mussels nan peaked beam rollers. Also spokes of the island too much will cause it not the height of the spokes fit rolling door shaft, to padded wire Poliglide into plastic bowl to increase the size of the barrel ring. 5. Door panels are called immediately when pulled down to about 2/3 of the door: When pulling the door down phenomenon 2/3 door crying in the barrel stuck to something but actually not entangled. Can store your books or increasing creep bamboomat was not enough, you need to loosen the screw a brake, loosen the screws 2 before the country should use pliers to hold the rotating shaft and prevent screw loosening party 2 . Then water pliers rotate clockwise to increase further until bamboomat enough screws tightened. (Note column of the book very well, if you do not call your specialist repairer should not perform this dangerous) 6. Doors blown off the rails (Lotto rollers) For slot door open: You need to open the itinerary box (box with plastic lid or metal on the surface motor) round screw loosening the wheel of the journey on the Council ( as the left hand side wheels when looked at) and then slightly turn hand wheel to wheel this contract moves toward the middle of the journey axis) then you hit the door down, note down when the door you have to the adjustable arm on the door body and grab rails to avoid stranded 2 screws to push the edge of the door at the same nipple slipped into the rails (if you have reversed the door manually stop). When the door was on the track you have to go down the door, the door will fall 1 sometimes heard loud distance but you do not pay attention because that body should drop door when the door is being dragged down by the drop will last pieces fit again. After you hit the door all the way down to the back door until the door on the wall about 50cm from the edge of the door you hit stop, adjust the wheel Council (Limit switch you just adjust to the correct position to disconnect at the door as you point out)
Being translated, please wait..