Foundation is a direct basis, carry out the ground improvement under the foundation.
And basic is the organic soil is located in the GL-2.35m and support layer, the basic lower end GL-1.35m, and 1.55m.
- Allowable bearing capacity of the ground than the boring test results, calculated by using the second paragraph (1) Building Standards Law Notification H13 No. 1113.
• The basis for the design, axial force is the fulcrum reaction force, moment by adding the moment of foundation bottom position by the shear force of the pedestal to the moment of the fulcrum
design.
And ownership at the time of the bending moment is to make sure that it does not exceed the ultimate strength of the foundation.
And study of liquefaction was carried out, FL value is to ensure that there is a low possibility of liquefaction are over 1.0.
- Do the assumption of consolidation settlement amount, member deformation angle is to make sure that does not exceed the lower limit deformation angle of "building foundation structure design guidelines".