In this simulation, system step response was studied.
Suppose unite step signal r 1 was added to the system. To
validate the effectiveness of the proposed approach, the
proposed FSPSMC was compared with a Smith predictor PID
with feedforward compensation control, which can be
obtained by substituting SMC in Fig. 2 by PID. The
parameters of these two control algorithms were listed in
Table I.